Definition:
AN ITEM GENERALLY CONSISTING OF ONE OR MORE TURNS OF WIRE OR SIMILAR CONDUCTIVE MATERIAL (IN SPECIAL CASES IT MAY BE CONSIDERED AS A PARTIAL TURN). IT IS SPECIFICALLY DESIGNED TO CONCENTRATE MAGNETIC FLUX GENERATED BY THE FLOW OF AN ELECTRIC CURRENT, TO INDUCE IN ITSELF AN ELECTROMOTIVE FORCE, AND TO ADD OR SUBTRACT INDUCTIVE REACTANCE IN A CIRCUIT. IT MAY INCLUDE TUNING DEVICES, INTEGRAL RESISTORS AND CAPACITORS; HOWEVER, EXCLUDES FILTER (AS MODIFIED). FOR COILS WOUND ON RESISTORS WHICH ARE DESIGNED TO BE INSERTED INTO THE CIRCUIT OF A RADIO FREQUENCY STAGE TO SUPPRESS HIGH FREQUENCY PARASITIC OSCILLATIONS, SEE SUPPRESSOR, PARASITIC..
CAGE Information
Code | Company |
---|---|
13483 | PRECISION ELECTRONICS INC. |
Federal Supply Class
Title
COILS AND TRANSFORMERS
Inclusions:
INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.
Exclusions:
Characteristics (Decoded)
MRC | Requirements Statement | Clear Text Reply |
---|---|---|
CRGS | DC RESISTANCE RATING IN OHMS | 0.025 SINGLE COMPONENT ALL WINDING |
ACYV | INDUCTANCE RATING | 0.40 MILLIHENRIES NOMINAL SINGLE COMPONENT ALL WINDING |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING |
AAJD | THREAD CLASS (NON-CORE) | 2B SINGLE GROUP |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
THSD | THREAD SERIES DESIGNATOR | UNC SINGLE GROUP |
AKDX | WINDING QUANTITY | 2 SINGLE COMPONENT |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AAJF | THREAD DIRECTION (NON-CORE) | RIGHT-HAND SINGLE GROUP |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
ACZR | CORE CONSTRUCTION | S0LID SINGLE COMPONENT |
ACZB | FREQUENCY RATING | 100.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.112 INCHES SINGLE GROUP |
CWJS | WINDING OPERATING VOLTAGE | 17.04 AC POUNDS PER HOUR WET SINGLE COMPONENT ALL WINDING |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
CQPZ | WINDING CONDUCTOR SIZE | 0.02535 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT ALL WINDING |
ADAV | OVERALL DIAMETER | 0.740 INCHES MINIMUM AND 0.780 INCHES MAXIMUM |
CRBZ | WINDING OPERATING CURRENT | 2.6 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT ALL WINDING |
CBME | CUBIC MEASURE (NON-CORE) | 1.96 CUBIC INCHES |
ADAQ | BODY LENGTH | 0.700 INCHES MINIMUM AND 0.800 INCHES MAXIMUM |